Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Braz. j. med. biol. res ; 52(4): e8006, 2019. tab, graf
Article in English | LILACS | ID: biblio-1001515

ABSTRACT

The aim of the study was to evaluate the diagnostic accuracy of thromboelastometry for assessing rivaroxaban concentrations. The accuracy of thromboelastometry was compared with the high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method, which is the gold standard for drug plasma monitoring (the reference standard). Forty-six clinically stable patients were treated with 10, 15, or 20 mg of rivaroxaban once daily (OD group) or 15 mg twice a day (BID group) (no particular indication for treatment). Patient samples were collected 2 h after the use of the medication (peak) and 2 h before the next dose (trough). The rivaroxaban plasma concentrations were determined via HPLC-MS/MS, and thromboelastometry was performed using a ROTEM® delta analyzer. There were significant prolongations in clotting time (CT) for the 10, 15, and 20 mg of rivaroxaban treatments in the OD groups. In the 15 mg BID group, the responses at the peak and trough times were similar. At the peak times, there was a positive correlation between the plasma concentration of rivaroxaban and CT (Spearman correlation rho=0.788, P<0.001) and clot formation time (rho=0.784, P<0.001), and a negative correlation for alpha angle (rho=−0.771, P<0.001), amplitude after 5 min (rho=−0.763, P<0.001), and amplitude after 10 min (rho=−0.680, P<0.001). The CT presented higher specificity and sensitivity using the cut-off determined by the receiver characteristics curve. ROTEM has potential as screening tool to measure possible bleeding risk associated with rivaroxaban plasma levels.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Drug Monitoring/methods , Factor Xa Inhibitors/blood , Rivaroxaban/blood , Hemorrhage/prevention & control , Thrombelastography , Blood Coagulation Tests , Chromatography, High Pressure Liquid , Tandem Mass Spectrometry , Factor Xa Inhibitors/administration & dosage , Rivaroxaban/administration & dosage , Data Accuracy
2.
Rev. méd. Chile ; 142(11): 1392-1397, nov. 2014. graf, tab
Article in Spanish | LILACS | ID: lil-734874

ABSTRACT

Background: The therapeutic range (TR) of activated partial thromboplastin time (aPTT) for unfractionated heparin (UFH) dosing was established in the 1970 decade. Since then aPTT determination has changed. Current TR may be sub or supra-therapeutic depending on the reagents of the test, and therefore, responsible for complications of therapy. Aim: To establish the TR for UFH dosing in our institution using antifactor Xa analysis as reference standard. Material and Methods: After obtaining an informed consent, 43 blood samples were obtained for aPTT determination and antifactor Xa assay in 23 patients treated with intravenous UFH. Samples were processed at Emergency and Hemostasis Labs. We excluded patients receiving other anticoagulants, with thrombophilia, pregnancy or liver disease. Results: Mean aPTT values in the Hemostasis and Emergency labs ​​were 57.1 ± 18.9 and 56.6 ± 18.3 seconds, respectively (p = 0.77). The squared correlation coefficients between aPTT and antifactor Xa at hemostasis and emergency labs were R2 0.5 and 0.45 respectively, p < 0.001. Using a linear regression analysis, therapeutic aPTT range values ​​in our laboratory were established between 50 and 80 seconds, corresponding to antifactor Xa values of 0.3 to 0.7 IU/mL. Conclusions: According to current recommendations, validation of aPTT determination with reference techniques should be done in every institution.


Subject(s)
Humans , Anticoagulants/administration & dosage , Factor Xa Inhibitors/blood , Heparin/administration & dosage , Partial Thromboplastin Time/methods , Indicators and Reagents , Nomograms , Reference Standards , Reference Values , Regression Analysis , Reproducibility of Results , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL